DEVICE: StatSensor (00385480506687)
Device Identifier (DI) Information
StatSensor
1.0
In Commercial Distribution
50668
NOVA BIOMEDICAL CORPORATION
1.0
In Commercial Distribution
50668
NOVA BIOMEDICAL CORPORATION
StatSensor Creatinine Meter with Battery and Quick Reference Guide
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
56668 | Metabolic profile clinical chemistry analyser IVD, portable, semi-automated |
A portable mains electricity (AC-powered) laboratory instrument, which may include internal rechargeable batteries, intended to be used for the qualitative and/or quantitative in vitro measurement of multiple clinical chemistry analytes to generate a metabolic profile. Analytes may include pH, blood gas parameters (e.g., pO2, pCO2), electrolytes [e.g., sodium (Na2+), potassium (K+), chloride (Cl-)], glucose, urea, creatinine and sometimes in addition haemoximetry parameters [e.g., carboxy-haemoglobin (COHb), methaemoglobin (MetHb), total haemoglobin (totHb), hematrocrit (Hct)]. It operates with reduced technician involvement and automation of some procedural steps.
|
Obsolete | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
CGL | ELECTRODE, ION BASED, ENZYMATIC, CREATININE |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K070068 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Without Condensation |
Special Storage Condition, Specify: 0 ft to 15000 ft |
Storage Environment Temperature: between 15 and 40 Degrees Celsius |
Handling Environment Temperature: between 15 and 40 Degrees Celsius |
Storage Environment Humidity: between 0 and 90 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
034264b0-0963-4ddb-b00d-3089047598de
July 06, 2018
3
September 20, 2016
July 06, 2018
3
September 20, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10385480506684 | 1 | 00385480506687 | In Commercial Distribution | Carton |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)545-6682
info@novabio.com