DEVICE: STAT PROFILE (00385480528559)
Device Identifier (DI) Information
STAT PROFILE
PRIME ABG
In Commercial Distribution
52855
NOVA BIOMEDICAL CORPORATION
PRIME ABG
In Commercial Distribution
52855
NOVA BIOMEDICAL CORPORATION
Prime ABG w/ Scanner Analyzer
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
56671 | Blood gas analyser IVD, point-of-care |
A mains electricity (AC-powered) instrument intended to be used by health professionals at the point-of-care, and often in the laboratory, for the quantitative in vitro measurement of blood pH, partial pressure of oxygen (pO2) and/or partial pressure of carbon dioxide (pCO2), and the calculation of other blood gas parameters [e.g., bicarbonate (HCO3-), base excess, arterial-alveolar gradient] in a clinical specimen.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
JJX | Single (specified) analyte controls (assayed and unassayed) |
JJS | CONTROLS FOR BLOOD-GASES, (ASSAYED AND UNASSAYED) |
CHL | ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K110648 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Humidity: between 20 and 85 Percent (%) Relative Humidity |
Storage Environment Temperature: between 15 and 32 Degrees Celsius |
Special Storage Condition, Specify: 0 ft to 12000 ft |
Special Storage Condition, Specify: Without Condensation |
Handling Environment Temperature: between 15 and 32 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
55b2a299-1c17-469f-bb70-3ef2702fb9be
July 06, 2018
3
July 06, 2017
July 06, 2018
3
July 06, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10385480528556 | 1 | 00385480528559 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)545-6682
info@novabio.com