DEVICE: STAT PROFILE (00385480534208)
Device Identifier (DI) Information
STAT PROFILE
PRIME CCS COMP
In Commercial Distribution
53420
NOVA BIOMEDICAL CORPORATION
PRIME CCS COMP
In Commercial Distribution
53420
NOVA BIOMEDICAL CORPORATION
Remanufactured PRIME CCS Comp Analyzer
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
56672 | Blood gas/haemoximetry analyser IVD, point-of-care |
A mains electricity (AC-powered) instrument intended to be used by health professionals at the point-of-care, and often in the laboratory, for the quantitative in vitro measurement of blood pH, partial pressure of oxygen (pO2) and/or partial pressure of carbon dioxide (pCO2), and the measurement or calculation of other blood gas and co-oximetry parameters [e.g., bicarbonate (HCO3-), base excess, arterial-alveolar gradient, oxyhaemoglobin (O2Hb), deoxyhaemoglobin (HHb) or reduced haemoglobin (RHb), carboxy-haemoglobin (COHb), methaemoglobin (MetHb), sulfhaemoglobin (SHb), and total haemoglobin (totHb)] in a clinical specimen.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
CGA | GLUCOSE OXIDASE, GLUCOSE |
CHL | ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH |
JJS | CONTROLS FOR BLOOD-GASES, (ASSAYED AND UNASSAYED) |
CEM | ELECTRODE, ION SPECIFIC, POTASSIUM |
GKF | INSTRUMENT, HEMATOCRIT, AUTOMATED |
KHP | ACID, LACTIC, ENZYMATIC METHOD |
JFP | ELECTRODE, ION SPECIFIC, CALCIUM |
JIX | CALIBRATOR, MULTI-ANALYTE MIXTURE |
CGZ | ELECTRODE, ION-SPECIFIC, CHLORIDE |
JGS | ELECTRODE, ION SPECIFIC, SODIUM |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K141907 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Humidity: between 20 and 85 Percent (%) Relative Humidity |
Handling Environment Temperature: between 15 and 32 Degrees Celsius |
Special Storage Condition, Specify: 0 ft to 12000 ft |
Special Storage Condition, Specify: Without Condensation |
Storage Environment Temperature: between 15 and 32 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
2ead787f-c363-4b55-910c-26ea3af14706
July 06, 2018
3
July 06, 2017
July 06, 2018
3
July 06, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
10385480534205 | 1 | 00385480534208 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)545-6682
info@novabio.com
info@novabio.com