DEVICE: UNO NPWT 70CC Collection Canister (00849405001058)
Device Identifier (DI) Information
UNO NPWT 70CC Collection Canister
U-C070
In Commercial Distribution
GENADYNE BIOTECHNOLOGIES INC.
U-C070
In Commercial Distribution
GENADYNE BIOTECHNOLOGIES INC.
The UNO Canister comes in only 1 size, which is 70cc. It has a solidifier gel sheet inside to solidify any collected exudates. The canister is made out of ABS plastic material. At the suction interface, where it is connected to the UNO pump, there is a hydrophobic filter welded to it. The filter has a 0.2 micron pore size, which has a bacteria filtration efficiency (BFE) of over 99%. The UNO canister is a disposable single use item. It comes packaged in a medical grade paper pouch.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47404 | Negative-pressure wound therapy system canister |
A receptacle for the collection of excess interstitial fluid, exudate, and infectious materials from a dedicated dressing that has been applied for a vacuum-assisted wound closure procedure; commonly known as negative pressure wound therapy (NPWT). It is typically made of transparent disposable plastic materials and is connected to or placed into the NPWT system's vacuum pump. This receptacle is a single-use device that should be discarded, including its contaminated waste content, according to the environmental legislation by which the user is bound (e.g., incineration, recycling, landfill).
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
OMP | Negative Pressure Wound Therapy Powered Suction Pump |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
3e3e7c32-0637-4be0-b1a7-7f541b3d8955
June 16, 2023
1
June 08, 2023
June 16, 2023
1
June 08, 2023
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]