DEVICE: DIPLOMAT FT (04047844118108)

Device Identifier (DI) Information

DIPLOMAT FT
Pedicle screw, fenestrated, reduction, monoaxial
In Commercial Distribution
AB1330-65060
SIGNUS Medizintechnik GmbH
04047844118108
GS1

1
344203948 *Terms of Use
The modular DIPLOMAT® pedicle screw system is a rod-screw system that firmly connects two or more screws via the screw head and a rod using a force-fit or form-fit connection. Additional fixation elements, such as cross bars, hooks, connectors and washers, can also be used. The DIPLOMAT® pedicle screw system is applied temporarily to provide internal posterior stabilization until bone fusion in the lumbar or thoracic spine has taken place. The surgeon makes the final decision as to the indwelling time of the implant in the patient‘s body and the time when the implant is to be explanted. The pedicle screw system is implanted from a posterior approach. The implant is screwed into the vertebral body via the pedicle and it can be applied in a single segment or multiple segments. Implantation is facilitated by use of the specially developed accessories for inserting and positioning the implants. Only these accessories ensure safe use. Our product information provides further system-related information on the surgical method. If there are any preoperative uncertainties relating to the implant, information must be obtained from SIGNUS. Instruments specially developed by SIGNUS to ensure safe application are available for use with the implant system.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46651 Spinal bone screw, non-bioabsorbable
A small, threaded, implantable rod with a screw head and drive intended for internal spinal fixation by being screwed into the spine to hold a correction/stabilization device (e.g., rod, plate, tether) to bone; it is made of a material that is not chemically degraded or absorbed via natural body processes (e.g., surgical steel, titanium alloy, carbon fibre). It is available in various types (e.g., pedicle or transfacet, with a slotted, cross, star, or polygonal drive), and is typically used to provide immobilization and stabilization of spinal segments in the treatment of spinal instabilities or deformities. A screw head adaptor intended to stabilize a rod may be included with the screw.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
NKB Orthosis, Spinal Pedicle Fixation, For Degenerative Disc Disease
MNI Orthosis, Spinal Pedicle Fixation
MNH Orthosis, Spondylolisthesis Spinal Fixation
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K151704 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 0 and 35 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Ø6,5x60mm
CLOSE

Device Record Status

890e4863-eba2-49c2-a471-f2484cd83fcd
September 11, 2024
3
March 27, 2023
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
+49602391660
info@signus.com