DEVICE: DIPLOMAT FT (04047844118788)
Device Identifier (DI) Information
DIPLOMAT FT
Pedicle screw w/o tulip, fenestrated, polyaxial
In Commercial Distribution
AB0320-75075/S
SIGNUS Medizintechnik GmbH
Pedicle screw w/o tulip, fenestrated, polyaxial
In Commercial Distribution
AB0320-75075/S
SIGNUS Medizintechnik GmbH
The modular DIPLOMAT® pedicle screw system is a rod-screw system that firmly connects two or more screws via the screw head and a rod using a force-fit or form-fit connection. Additional fixation elements, such as cross bars, hooks, connectors and washers, can also be used. The DIPLOMAT® pedicle screw system is applied temporarily to provide internal posterior stabilization until bone fusion in the lumbar or thoracic spine has taken place. The surgeon makes the final decision as to the indwelling time of the implant in the patient‘s body and the time when the implant is to be explanted. The pedicle screw system is implanted from a posterior approach. The implant is screwed into the vertebral body via the pedicle and it can be applied in a single segment or multiple segments. Implantation is facilitated by use of the specially developed accessories for inserting and positioning the implants. Only these accessories ensure safe use. Our product information provides further system-related information on the surgical method. If there are any preoperative uncertainties relating to the implant, information must be obtained from SIGNUS. Instruments specially developed by SIGNUS to ensure safe application are available for use with the implant system.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46651 | Spinal bone screw, non-bioabsorbable |
A small, threaded, implantable rod with a screw head and drive intended for internal spinal fixation by being screwed into the spine to hold a correction/stabilization device (e.g., rod, plate, tether) to bone; it is made of a material that is not chemically degraded or absorbed via natural body processes (e.g., surgical steel, titanium alloy, carbon fibre). It is available in various types (e.g., pedicle or transfacet, with a slotted, cross, star, or polygonal drive), and is typically used to provide immobilization and stabilization of spinal segments in the treatment of spinal instabilities or deformities. A screw head adaptor intended to stabilize a rod may be included with the screw.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
NKB | Orthosis, Spinal Pedicle Fixation, For Degenerative Disc Disease |
MNH | Orthosis, Spondylolisthesis Spinal Fixation |
MNI | Orthosis, Spinal Pedicle Fixation |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K151704 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 0 and 35 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: Ø7,5x75mm |
Device Record Status
1d34af50-4e4f-431a-b562-f987ebc57104
September 11, 2024
3
March 27, 2023
September 11, 2024
3
March 27, 2023
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+49602391660
info@signus.com
info@signus.com