SEARCH RESULTS FOR: (*what is fsi pso billmatrix*)(2566060 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2712UA2
In Commercial Distribution

  • 04540778167735 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 12 mm
  • Balloon Diameter; 2.75 mm
DC-RY2712UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2510UA2
In Commercial Distribution

  • 04540778167575 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 2.5 mm
DC-RY2510UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2010UA2
In Commercial Distribution

  • 04540778167551 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 2.0 mm
DC-RY2010UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4508UA2
In Commercial Distribution

  • 04540778167490 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 4.5 mm
DC-RY4508UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3708UA2
In Commercial Distribution

  • 04540778167452 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 3.75 mm
DC-RY3708UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3208UA2
In Commercial Distribution

  • 04540778167414 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 3.25 mm
DC-RY3208UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2708UA2
In Commercial Distribution

  • 04540778167377 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 2.75 mm
DC-RY2708UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2508UA2
In Commercial Distribution

  • 04540778167353 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 2.5 mm
DC-RY2508UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2208UA2
In Commercial Distribution

  • 04540778167339 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 2.25 mm
DC-RY2208UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2008UA2
In Commercial Distribution

  • 04540778167315 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 2.0 mm
DC-RY2008UA2

  • Coronary angioplasty balloon catheter, basic
< 1 ... 863 864 865 866 867 ... 1000 >