The Model 2740 physician programmer is designed for use by a physician to non‐invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short‐range radio‐frequency (RF) telemetry; telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-061
In Commercial Distribution
- 00855728005338 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non‐invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short‐range radio‐frequency (RF) telemetry; telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-051
In Commercial Distribution
- 00855728005307 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
The Model 2740 physician programmer is designed for use by a physician to non‐invasively interrogate
and program the IPG. It is the only component in the Inspire system that contains software. This
programmer consists of a tablet computer and a telemetry cable. The telemetry head communicates
with the IPG through the skin via short‐range radio‐frequency (RF) telemetry; telemetry communication
allows the physician to noninvasively interrogate and program the IPG. The telemetry head is powered
by a wall outlet connection and wirelessly communicates (via wireless Bluetooth link) with the physician
programmer tablet. The physician programmer has the capability to monitor respiratory waveforms,
program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-004-041
In Commercial Distribution
- 00855728005277 ()
2740
- Antiseizure/psychiatric-therapy vagus nerve implantable electrical stimulation system
TRANSCYTE® is a human fibroblast-derived temporary skin substitute
consisting of a polymer membrane and donated neonatal human
fibroblast cells cultured under aseptic conditions in vitro on a nylon
mesh. Prior to cell growth, this nylon mesh is coated with porcine
dermal collagen and bonded to a polymer membrane (silicone). This
membrane provides a transparent synthetic epidermis when applied.
As fibroblasts proliferate within the nylon mesh, they secrete human
dermal collagen, matrix proteins and growth factors. Following freezing,
no cellular metabolic activity remains; however, the tissue matrix and
bound growth factors are left intact. The human fibroblast-derived
temporary skin substitute provides a temporary protective barrier.
TRANSCYTE is transparent and allows direct visual monitoring of the
wound bed.
ORGANOGENESIS INC.
10633
In Commercial Distribution
- 00618474000046 ()
- Skin regeneration template, human-/animal-derived
The TriVascular® Ovation Prime® Abdominal Stent Graft System is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required. The TriVascular Ovation Prime Abdominal Stent Graft System includes, an Aortic Body Stent Graft and delivery catheter, Iliac Limb Stent Grafts and delivery catheters, Iliac Extension Stent Grafts and delivery catheters, as required, a Fill Kit, and an Autoinjector.
Endologix, Inc.
TV-CS14-G
In Commercial Distribution
- 00850007370459 ()
- Total Volume: 14 Milliliter
TV-CS14-G
- Abdominal aorta endovascular stent-graft
The Heart Sync Sterile Adult Radio Transparent Multi Function Electrodes are indicated for use in
external pacing, defibrillation and monitoring applications as a sterile, disposable device for single
patient use only. The electrodes provide the conductive interface between the defibrillator and/or the
external transcutaneous (noninvasive) cardiac pacemaker and the patient's skin. The electrode is
intended for use on adult patients (>22lbs/10kg). When a patient requires defibrillation, cardioversion or external
pacing, these electrodes will be applied to the patient and connected to the instrument. This device is
intended for use on defibrillators whose output is classified as low power (360 joule maximum).
Compatible with "Anderson" adapted models of monophasic and bi-phasic
defibrillators.
HEART SYNC INC
Sterile-C100
Not in Commercial Distribution
- 10868866000032 ()
- 00868866000035 ()
Sterile-C100
- Electrode conductive skin pad, single-use
The Heart Sync Sterile Adult Radio Transparent Multi Function Electrodes are indicated for use in
external pacing, defibrillation and monitoring applications as a sterile, disposable device for single
patient use only. The electrodes provide the conductive interface between the defibrillator and/or the
external transcutaneous (noninvasive) cardiac pacemaker and the patient's skin. The electrode is
intended for use on adult patients (>22lbs/10kg). When a patient requires defibrillation, cardioversion or external
pacing, these electrodes will be applied to the patient and connected to the instrument. This device is
intended for use on defibrillators whose output is classified as low power (360 joule maximum).
Compatible with Zoll adapted models of monophasic and bi-phasic
defibrillators.
HEART SYNC INC
Sterile-C100-Zoll
Not in Commercial Distribution
- 10868866000025 ()
- 00868866000028 ()
Sterile-C100-Zoll
- Electrode conductive skin pad, single-use
The Heart Sync Sterile Adult Radio Transparent Multi Function Electrodes are indicated for use in
external pacing, defibrillation and monitoring applications as a sterile, disposable device for single
patient use only. The electrodes provide the conductive interface between the defibrillator and/or the
external transcutaneous (noninvasive) cardiac pacemaker and the patient's skin. The electrode is
intended for use on adult patients (>22lbs/10kg). When a patient requires defibrillation, cardioversion or external
pacing, these electrodes will be applied to the patient and connected to the instrument. This device is
intended for use on defibrillators whose output is classified as low power (360 joule maximum).
Compatible with Physio Control quik combo® adapted models of monophasic and bi-phasic
defibrillators.
HEART SYNC INC
Sterile-C100-Physio
Not in Commercial Distribution
- 10868866000018 ()
- 00868866000011 ()
Sterile-C100-Physio
- Electrode conductive skin pad, single-use
The TriVascular® Ovation Prime® Abdominal Stent Graft System is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required.
The TriVascular Ovation Prime Abdominal Stent Graft System includes, an Aortic Body Stent Graft and delivery catheter, Iliac Limb Stent Grafts and delivery catheters, Iliac Extension Stent Grafts and delivery catheters, as required, a Fill Polymer Kit, and an Autoinjector.
Trivascular, Inc.
Iliac Limb
In Commercial Distribution
- M701TVIL142280E1 ()
- Catheter Gauge: 15 French
- Length: 80 Millimeter
- Outer Diameter: 22 Millimeter
- Outer Diameter: 14 Millimeter
TV-IL142280-E
- Abdominal aorta endovascular stent-graft
The TriVascular® Ovation Prime® Abdominal Stent Graft System is an endovascular device delivered via a small diameter catheter to treat abdominal aortic aneurysms (AAAs). The stent graft is designed to reline the diseased vasculature, providing an endovascular blood conduit for isolating the aneurysm from the high pressure flow of blood, thereby reducing the risk of rupture. The stent graft is a modular configuration comprised of an aortic body section, iliac limbs, and iliac extensions as required.
The TriVascular Ovation Prime Abdominal Stent Graft System includes, an Aortic Body Stent Graft and delivery catheter, Iliac Limb Stent Grafts and delivery catheters, Iliac Extension Stent Grafts and delivery catheters, as required, a Fill Polymer Kit, and an Autoinjector.
Trivascular, Inc.
Iliac Limb
In Commercial Distribution
- M701TVIL1422140E1 ()
- Catheter Gauge: 15 French
- Length: 140 Millimeter
- Outer Diameter: 22 Millimeter
- Outer Diameter: 14 Millimeter
TV-IL1422140-E
- Abdominal aorta endovascular stent-graft