SEARCH RESULTS FOR: (*what is fsi pso billmatrix*)(67376 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Paragon HDS® (paflufocon B) rigid gas permeable contact lenses for daily wear are available as lathe cut or molded firm contact lenses with spherical, aspheric, bifocal or toric anterior and/or posterior; or, bitoric surfaces in tinted versions. Paragon HDS® rigid gas permeable contact lenses for extended wear are available as lathe cut or molded firm contact lenses with spherical or aspheric anterior or posterior surfaces in tinted versions. The posterior curve is selected so as to properly fit an individual eye and the anterior curve is selected to provide the necessary optical power to correct refractive error. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea.
The Paragon HDS® rigid gas permeable contact lens material is a thermoset copolymer derived from fluorosilicone acrylate monomers.
The Paragon HDS® rigid gas permeable tinted lenses offer color enhancement of the eye and a handling aid for locating the lens. These products may be plasma treated.
Paragon Vision Sciences, Inc.
Paragon HDS
In Commercial Distribution
- B22208 ()
- Orthokeratology contact lens
- Rigid-gas-permeable corrective contact lens, daily-wear
- Rigid-gas-permeable corrective contact lens, extended-wear
FluoroPerm® 60 (paflufocon B) rigid gas permeable contact lenses for daily wear are available as lathe cut or molded firm contact lenses with spherical, aspheric, bifocal or toric anterior and/or posterior; or, bitoric surfaces in clear and tinted versions. FluoroPerm® 60 rigid gas permeable contact lenses for extended wear are available as lathe cut or molded firm contact lenses with spherical or aspheric anterior or posterior surfaces in clear and tinted versions. The posterior curve is selected so as to properly fit an individual eye and the anterior curve is selected to provide the necessary optical power to correct refractive error. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea.
The FluoroPerm® 60 rigid gas permeable contact lens material is a thermoset copolymer derived from fluorosilicone acrylate monomers.
FluoroPerm® 60 rigid gas permeable tinted lenses offer a handling aid for locating the lens. These products may be plasma treated.
Paragon Vision Sciences, Inc.
Fluoroperm 60
In Commercial Distribution
- B22205 ()
- Rigid-gas-permeable corrective contact lens, daily-wear
- Rigid-gas-permeable corrective contact lens, extended-wear
FluoroPerm® 92 (paflufocon A) rigid gas permeable contact lenses for daily wear are available as lathe cut or molded firm contact lenses with spherical, aspheric,bifocal or toric anterior and/or posterior; or, bitoric surfaces in clear and tinted versions. FluoroPerm 92 rigid gas permeable contact lenses for extended wear are available as lathe cut or molded firm contact lenses with spherical or aspheric anterior or posterior surfaces in clear and tinted versions. The posterior curve is selected so as to properly fit an individual eye and the anterior curve is selected to provide the necessary optical power to correct refractive error. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea.
The FluoroPerm® 92 rigid gas permeable contact lens material is a thermoset copolymer derived from fluorosilicone acrylate monomers.
FluoroPerm® 92 rigid gas permeable tinted lenses offer a handling aid for locating the lens. These products may be plasma treated.
Paragon Vision Sciences, Inc.
Fluoroperm 92
In Commercial Distribution
- B22204 ()
- Rigid-gas-permeable corrective contact lens, daily-wear
- Rigid-gas-permeable corrective contact lens, extended-wear
Paraperm® EW (pasifocon C) rigid gas permeable contact lenses for daily wear are available as lathe cut or molded firm contact lenses with spherical, aspheric, bifocal or toric anterior and/or posterior; or, bitoric surfaces in clear and tinted versions. Paraperm® EW rigid gas permeable contact lenses for extended wear are available as lathe cut or molded firm contact lenses with spherical or aspheric anterior or posterior surfaces in clear and tinted versions. The posterior curve is selected so as to properly fit an individual eye and the anterior curve is selected to provide the necessary optical power to correct refractive error. A peripheral curve system on the posterior surface allows tear exchange between the lens and the cornea.
The Paraperm® EW rigid gas permeable contact lens material is a thermoset copolymer derived from siloxane and methylmethacrylate.
The Paraperm® EW rigid gas permeable tinted lenses offer a handling aid for locating the lens.
Paragon Vision Sciences, Inc.
Paraperm EW
In Commercial Distribution
- B22203 ()
- Rigid-gas-permeable corrective contact lens, daily-wear
- Rigid-gas-permeable corrective contact lens, extended-wear
Belotero Balance is a hyaluronic-acid based dermal filler approved for injection into the mid-to-deep dermis for correction of moderate-to-severe facial wrinkles and folds, such as nasolabial folds. Belotero Balance kit contains (1) injectable implant and 2 needles - 30 Gauge x 1/2 inch, and 27 Gauge x 1/2 inch.
MERZ NORTH AMERICA, INC.
8700M0
Not in Commercial Distribution
- M2138700M05 ()
- Total Volume: 1 Milliliter
- Dermal tissue reconstructive material, microbe-derived
The OrganOx metra® is a transportable device intended to be used to sustain donor livers destined for transplantation in a functioning state for a total preservation time of up to 12 hours.
The OrganOx metra® device is suitable for liver grafts from donors after brain death (DBD), or liver grafts from donors after circulatory death (DCD) less than or equal to 40 years old, with less than or equal to 20 mins of functional warm ischemic time (time from donor systolic blood pressure less than 50 mmHg), and macrosteatosis less than or equal to 15%, in a near-physiologic, normothermic and functioning state intended for a potential transplant recipient.
ORGANOX LIMITED
D0146
In Commercial Distribution
- 05060462240029 ()
- Liver donor-organ preservation/transport system
CELLUGEL 1.0ML 25G
CELLUGEL® Ophthalmic Viscosurgical Device (OVD) is a sterile, nonpyrogenic, noninflammatory viscoelastic solution of highly purified non-proteinaceous 2% Hydroxypropyl Methylcellulose (HPMC) with an average molecular weight of 300,000
daltons dissolved in an isotonic, physiological buffer.
Each mL of CELLUGEL® contains: 2% HPMC, 0.525% sodium chloride, 0.075% potassium chloride, 0.048% calcium chloride dihydrate, 0.03% magnesium chloride hexahydrate, 0.39% sodium acetate trihydrate, 0.17% sodium citrate dihydrate, and water for injection. Sodium hydroxide and/or hydrochloric acid may be used as pH adjusters. The osmolarity of CELLUGEL® is 315 ± 35 mOsM/kg, the pH 7.2 ± 0.4, and the viscosity 30,000 ± 10,000 cps (at 0.2 sec-1, 25°C).
Alcon Laboratories, Inc.
8065183810
In Commercial Distribution
- 00380651838109 ()
- 20380651838103 ()
- Total Volume: 1 Milliliter
- Aqueous/vitreous humour replacement medium kit
The Model 2740S SleepSync Programmer Application is a standalone software that is downloaded and installed on a user-owned computer and paired by the user (clinician) with the Model 2740C Programmer Cable to non-invasively interrogate and program the Implantable Pulse Generator (IPG) of the Inspire Upper Airway Stimulation (UAS) System. The SleepSync Programmer Application provides the graphic user interface (GUI) for the SleepSync Programmer System (Model 2740S and Model 2740C) while the Programmer Cable provides the communications interface between the SleepSync Programmer Application and the IPG. The SleepSync Programmer Application has the capability to monitor respiratory waveforms, program stimulation modes, adjust stimulation parameter values, and store waveforms and settings.
Inspire Medical Systems, Inc.
900-029-001
In Commercial Distribution
- 00810098650038 ()
2740S
- Implantable sleep apnoea treatment system, respiration-sensing
The Inspire® Respiratory Sensing Lead (Model 4340) is designed to detect respiratory effort. The lead features a pressure sensitive membrane that converts the mechanical energy of respiration into an electrical signal. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG) for treatment of obstructive sleep apnea.
Inspire Medical Systems, Inc.
900-014-003
In Commercial Distribution
- 00855728005949 ()
4340
- Implantable sleep apnoea treatment system, respiration-sensing
The Inspire® Respiratory Sensing Lead (Model 4340) is designed to detect respiratory effort. The lead features a pressure sensitive membrane that converts the mechanical energy of respiration into an electrical signal. The lead incorporates a standard connector for coupling to the Inspire implantable pulse generator (IPG) for treatment of obstructive sleep apnea.
Inspire Medical Systems, Inc.
900-014-005
In Commercial Distribution
- 10810098650301 ()
4340
- Implantable sleep apnoea treatment system, respiration-sensing