R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q60020ER
In Commercial Distribution
- 04540778174931 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 6.0 mm
BD-Q60020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q50020ER
In Commercial Distribution
- 04540778174917 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 5.0 mm
BD-Q50020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q40020ER
In Commercial Distribution
- 04540778174894 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 4.0 mm
BD-Q40020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q30020ER
In Commercial Distribution
- 04540778174870 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 3.0 mm
BD-Q30020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q25020ER
In Commercial Distribution
- 04540778174856 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.5 mm
BD-Q25020ER
- Peripheral angioplasty balloon catheter, basic
R2P CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. R2P CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-Q20020ER
In Commercial Distribution
- 04540778174832 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 2000 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.0 mm
BD-Q20020ER
- Peripheral angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4030UA2
In Commercial Distribution
- 04540778168473 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.1 Fr
- Distal Shaft Diameter; 2.7 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 30 mm
- Balloon Diameter; 4.0 mm
DC-RY4030UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3530UA2
In Commercial Distribution
- 04540778168459 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 30 mm
- Balloon Diameter; 3.5 mm
DC-RY3530UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3030UA2
In Commercial Distribution
- 04540778168435 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 30 mm
- Balloon Diameter; 3.0 mm
DC-RY3030UA2
- Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2530UA2
In Commercial Distribution
- 04540778168411 ()
- Maximum Guidewire Diameter; 0.014 inch
- Compatible Guiding Catheter; 5 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 6 atm
- Proximal Shaft Diameter; 2.0 Fr
- Distal Shaft Diameter; 2.5 Fr
- Catheter Working Length; 1450 mm
- Balloon Length; 30 mm
- Balloon Diameter; 2.5 mm
DC-RY2530UA2
- Coronary angioplasty balloon catheter, basic