SEARCH RESULTS FOR: (*what is fsi pso billmatrix*)(1512543 results)

Export results
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
Company Name Brand Name GMDN Term Name GMDN Term Status FDA Product Code Name FDA Product Code Device Packaged As Sterile Sterilization Prior To Use Issuing Agency Device Size Device Size Type Device Class Implantable

Show Filters

OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY3220UA2
In Commercial Distribution

  • 04540778169579 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 3.25 mm
DC-PY3220UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY3020UA2
In Commercial Distribution

  • 04540778169555 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 3.0 mm
DC-PY3020UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY2720UA2
In Commercial Distribution

  • 04540778169531 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 2.75 mm
DC-PY2720UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY2520UA2
In Commercial Distribution

  • 04540778169517 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 2.5 mm
DC-PY2520UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY2220UA2
In Commercial Distribution

  • 04540778169494 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 2.25 mm
DC-PY2220UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY2020UA2
In Commercial Distribution

  • 04540778169470 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 2.0 mm
DC-PY2020UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY1520UA1
In Commercial Distribution

  • 04540778169456 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 1.5 mm
DC-PY1520UA1

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY5015UA2
In Commercial Distribution

  • 04540778169432 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 2.8 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 15 mm
  • Balloon Diameter; 5.0 mm
DC-PY5015UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY3715UA2
In Commercial Distribution

  • 04540778169371 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.8 Fr
  • Distal Shaft Diameter; 2.8 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 15 mm
  • Balloon Diameter; 3.75 mm
DC-PY3715UA2

  • Coronary angioplasty balloon catheter, basic
OTW TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. OTW TAKERU is an over the wire (OTW) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-PY3215UA2
In Commercial Distribution

  • 04540778169333 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 3.3 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 15 mm
  • Balloon Diameter; 3.25 mm
DC-PY3215UA2

  • Coronary angioplasty balloon catheter, basic
< 1 ... 386 387 388 389 390 ... 1000 >