SEARCH RESULTS FOR: (*what is fsi pso billmatrix*)(1512543 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
PROGREAT Microcatheter System
TERUMO CORPORATION
MC*PC2013Y
In Commercial Distribution
- 54987350727362 ()
- 04987350727367 ()
- Outer Diameter: 0.67 Millimeter
- Length: 130 Centimeter
- Clinically Relevant Size 1 is relative to catheter distal end. And other Clinically Relevant Sizes are relative to catheter shaft.
MC*PC2013Y
- Vascular microcatheter
PROGREAT Microcatheter System
TERUMO CORPORATION
MC*PC2011Y
In Commercial Distribution
- 54987350727348 ()
- 04987350727343 ()
- Length: 110 Centimeter
- Outer Diameter: 0.67 Millimeter
- Clinically Relevant Size 1 is relative to catheter distal end. And other Clinically Relevant Sizes are relative to catheter shaft.
MC*PC2011Y
- Vascular microcatheter
PROGREAT Microcatheter System
TERUMO CORPORATION
MC*PV2415Y
In Commercial Distribution
- 54987350718445 ()
- 04987350718440 ()
- Clinically Relevant Size 1 is relative to catheter distal end. And other Clinically Relevant Sizes are relative to catheter shaft.
- Outer Diameter: 0.80 Millimeter
- Length: 150 Centimeter
MC*PV2415Y
- Vascular microcatheter
PROGREAT Microcatheter System
TERUMO CORPORATION
MC*PV2815Y
In Commercial Distribution
- 54987350718421 ()
- 04987350718426 ()
- Clinically Relevant Size 1 is relative to catheter distal end. And other Clinically Relevant Sizes are relative to catheter shaft.
- Outer Diameter: 0.93 Millimeter
- Length: 150 Centimeter
MC*PV2815Y
- Vascular microcatheter
The Tasso+ Kit is a kit that includes the Tasso+ device and all supplies necessary to collect a blood sample. The Tasso+ device is a sterile, disposable blood lancing device. When collecting a sample, the device is held onto the skin by a mild adhesive. A sterile lancet punctures the skin with a press of the button, simultaneously this creates a slight vacuum that helps capillary blood flow under gravity into a compatible tube. After a predefined time period, or when the tube is full, the device is peeled off the skin. The tube is removed and capped for transport. The lancet is single use and automatically retracts into the device in a safe position after use.
Quest Diagnostics
Exempt
In Commercial Distribution
- 00810121520000 ()
- Manual blood lancing device, reusable
NEOVEIL Staple Line Reinforcement is composed of a biodegradable synthetic polymer, polyglycolic acid(PGA) and is offered as a nonwoven surgical mesh configured into sleeves. The device is applied to the surgical site via a mechanical stapler with two jaws, where one piece of the sleeve is slid over each jaw of the stapler. This is accomplished by attaching a similar-sized piece of nonabsorbable elastic knit to the PGA felt that is held together by means of PGA tacking threads. After deployment of the tube type reinforcement material, the non-degradable elastic knits, comprised of polyurethane and nylon, are removed and discarded along with the PGA tacking sutures. The PGA material is dyed with D&C Green No.6.
GUNZE LIMITED
NV-ET-M60E-3
In Commercial Distribution
- 04973077713776 ()
- Length: 60 Millimeter
- Width: 17 Millimeter
NV-ET-M60E-3
- Extra-gynaecological surgical mesh, synthetic polymer, bioabsorbable
THREADED RIGHT ANGLE CONNECTOR
One end of the Threaded Right-Angle Connector is identical to the ends of the standard connector. The other end is manufactured with threads to join spring-reinforced ventricular catheters to plain silicone elastomer tubing and flushing devices were a 90 degree bend is desired, and when the bendable feature of a spring-reinforced ventricular catheter is not utilized. A reduced diameter tip facilitates insertion of a connector into a catheter tube. A single groove is considered standard and is located near each connector end to accommodate a ligature. This type of end is inserted into flushing devices and all catheters that are not spring-reinforced. The connector threads help improve the grip between the connected and the catheter.
Integra Lifesciences Corporation
NL8501913
Not in Commercial Distribution
- 10381780024392 ()
- M269NL85019131 ()
- 1.1mm ID x 1.9mm OD (all dimensions nominal)
NL8501913
- Cerebrospinal fluid shunt connector
The Geri Dish is intended to be used for preparation, storage and imaging of human embryos. The Geri Dish is intended to be used only with the Geri Embryo Incubator.
GENEA BIOMEDX PTY LTD
GERI-DSH-20
In Commercial Distribution
- 29348265003011 ()
- 19348265003014 ()
- 09348265003017 ()
- Assisted reproduction procedure dish
LUMIFLEX 3-STAGE Balloon Dilatation Catheter 8.0 cm-18mm wire is made of nylon and is a progressive stage balloon capable of three disctinct and progressively larger diameters via controlled radial expansion.
US Endoscopy
00718018W
In Commercial Distribution
- 00724995244712 ()
- Guidewire Diameter: 0.89 Millimeter
- Balloon Length: 8 Centimeter
- Catheter Length: 180 Centimeter
00718018W
- Gastrointestinal/biliary dilation balloon catheter, non-medicated
LUMIFLEX 3-STAGE Balloon Dilatation Catheter 8.0cm/15mm wire is made of nylon and is a progressive stage balloon capable of three disctinct and progressively larger diameters via controlled radial expansion.
US Endoscopy
00718015W
In Commercial Distribution
- 00724995244705 ()
- Balloon Length: 8 Centimeter
- Catheter Length: 180 Centimeter
- Guidewire Diameter: 0.89 Millimeter
00718015W
- Gastrointestinal/biliary dilation balloon catheter, non-medicated