SEARCH RESULTS FOR: (*what is fsi pso billmatrix*)(1512543 results)
Only the first 10,000 results were returned. Filter these results or refine your query. Some pre-built queries with more than 10,000 results are available for download.
INTEGRA Dermal Regeneration Template 4in. x 10in. (10cm x 25cm) is a bilayer membrane system for skin replacement. The dermal replacement layer is made of a porous matrix of fibers of cross-linked bovine tendon collagen and a glycosaminoglycan (chondroitin-6-sulfate) that is manufactured with a controlled porosity and defined degradation rate. The epidermal substitute layer is made of a thin polysiloxane (silicone) layer to control moisture loss from the wound.
Integra Lifesciences Corporation
34105
In Commercial Distribution
- M269341051 ()
- 10381780000594 ()
- 00381780000597 ()
- 4 in x 10 in
34105
- Animal-derived wound matrix dressing
INTEGRA Dermal Regeneration Template 4in. x 5in. (10cm x 12.5cm) is a bilayer membrane system for skin replacement. The dermal replacement layer is made of a porous matrix of fibers of cross-linked bovine tendon collagen and a glycosaminoglycan (chondroitin-6-sulfate) that is manufactured with a controlled porosity and defined degradation rate. The epidermal substitute layer is made of a thin polysiloxane (silicone) layer to control moisture loss from the wound.
Integra Lifesciences Corporation
34055
In Commercial Distribution
- M269340551 ()
- 10381780000570 ()
- 00381780000573 ()
- 4 in x 5 in
34055
- Animal-derived wound matrix dressing
INTEGRA Dermal Regeneration Template 2in. x 2in. (5cm x 5cm) is a bilayer membrane system for skin replacement. The dermal replacement layer is made of a porous matrix of fibers of cross-linked bovine tendon collagen and a glycosaminoglycan (chondroitin-6-sulfate) that is manufactured with a controlled porosity and defined degradation rate. The epidermal substitute layer is made of a thin polysiloxane (silicone) layer to control moisture loss from the wound.
Integra Lifesciences Corporation
32025
In Commercial Distribution
- M269320251 ()
- 10381780000556 ()
- 00381780000559 ()
- 2 in x 2 in
32025
- Animal-derived wound matrix dressing
A flexible manual device intended to be used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with grasping tongs which are operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a single-use device.
HOBBS MEDICAL, INC.
5030S
In Commercial Distribution
- M8495030S0 ()
- M8495030S1 ()
5030S
- Flexible endoscopic tissue manipulation forceps, single-use
A flexible manual device intended to be used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with grasping tongs which are operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a single-use device.
HOBBS MEDICAL, INC.
5030
In Commercial Distribution
- M84950300 ()
5030
- Flexible endoscopic tissue manipulation forceps, single-use
A flexible manual device intended to be used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with grasping tongs which are operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reuseable device.
HOBBS MEDICAL, INC.
5018
In Commercial Distribution
- M84950180 ()
5018
- Flexible endoscopic tissue manipulation forceps, reusable
A flexible manual device intended to be used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with grasping tongs which are operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reuseable device.
HOBBS MEDICAL, INC.
5008
In Commercial Distribution
- M84950080 ()
5008
- Flexible endoscopic tissue manipulation forceps, reusable
A flexible manual device intended to be used in combination with a compatible endoscope to grasp foreign bodies. It is constructed of a flexible metal coil and plastic tube whose distal end is equipped with grasping tongs which are operated by a control handle attached at the proximal end of the instrument. It is introduced into the body cavity through the working channel of the endoscope. This is a reuseable device.
HOBBS MEDICAL, INC.
5004
In Commercial Distribution
- M84950040 ()
5004
- Flexible endoscopic tissue manipulation forceps, reusable
HTC (high temperature cautery) F7244/1 model is a sterile bipolar battery operated disposable device used for the cauterization of tissues and capillary vessels. F7244/1 model is equipped with fine tip that permits the cauterization of very small vessels and is suitable to be used all the times a quick and precise cauterization is necessary. F7244/1 reaches a maximum working temperature of 1.200°C (2.200 °F).
FIAB SPA
F7244/1
Not in Commercial Distribution
- 18033695727456 ()
- 28033695727453 ()
- 38033695727450 ()
F7244/1
- Electrocautery system generator, battery-powered
Tobra Bone Basket- autograft bone collection system with mesh filter and graft compressor
Tobra Medical, Inc.
BB-100
In Commercial Distribution
- 10852360007000 ()
- 00852360007003 ()
BB-100
- Orthopaedic surgery tissue debris collector, single-use