CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F20040MR
In Commercial Distribution
- 04540778157576 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 40 mm
- Balloon Diameter; 2.0 mm
BD-F20040MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F60020MR
In Commercial Distribution
- 04540778157552 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 6.0 mm
BD-F60020MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F50020MR
In Commercial Distribution
- 04540778157538 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 5.0 mm
BD-F50020MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F40020MR
In Commercial Distribution
- 04540778157514 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 4.0 mm
BD-F40020MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F30020MR
In Commercial Distribution
- 04540778157491 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 3.0 mm
BD-F30020MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F25020MR
In Commercial Distribution
- 04540778157477 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.5 mm
BD-F25020MR
- Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F20020MR
In Commercial Distribution
- 04540778157453 ()
- Maximum Guidewire Diameter; 0.018 inch
- Compatible Sheath Diameter; 4 Fr
- Rated Burst Pressure; 14 atm
- Nominal Pressure; 8 atm
- Proximal Shaft Diameter; 3.4 Fr
- Distal Shaft Diameter; 4.0 Fr
- Catheter Working Length; 900 mm
- Balloon Length; 20 mm
- Balloon Diameter; 2.0 mm
BD-F20020MR
- Peripheral angioplasty balloon catheter, basic
The VT300 is a wall-mounted radiographic cassette holder. A wall-mounted radiographic cassette holder is a device that is a support intended to hold and position radiographic cassettes for a radiographic exposure for medical use.
Del Medical, Inc.
VT300 (5150)
In Commercial Distribution
- 00858340006363 ()
- X-ray film cassette holder
The VT300 is a wall-mounted radiographic cassette holder. A wall-mounted radiographic cassette holder is a device that is a support intended to hold and position radiographic cassettes for a radiographic exposure for medical use.
Del Medical, Inc.
VT300 (5157)
In Commercial Distribution
- 00858340006356 ()
- X-ray film cassette holder
The VS300 is a wall-mounted radiographic cassette holder. A wall-mounted radiographic cassette holder is a device that is a support intended to hold and position radiographic cassettes for a radiographic exposure for medical use.
Del Medical, Inc.
VS300
In Commercial Distribution
- 00858340006349 ()