The titanium alloy SNAP-OFF screws are dedicated for the fixation of the HALLU-C and HALLU-S plates. They are available in different diameters and sizes. They exist in different colors for size identification. The unthreaded part provides the system with the mechanism for the bone to slide along this unthreaded body. The design of the thread allows the snap-off screw to be self tapping so that no pre-tap is required when implanting the device .The distal end of the snap-off screw has a smooth tip to protect tissues.
NEWDEAL
117010ND
In Commercial Distribution
- M248117010ND1 ()
- 10381780047476 ()
- 2.7mm diam. x 10mm length
117010ND
- Orthopaedic bone screw, non-bioabsorbable, non-sterile
AUTO REF/KERATO/TONOMETER Model TONOREF II is designed to singly perform objective refraction, corneal shape measurement, and non-contact tonometry measurement by incorporating a standard auto ref/keratometer and non-contact tonometer into one unit. The objective refraction function measures spherical powers, cylindrical powers and cylinder axis. The corneal shape measurement function measures the radius of corneal curvature (corneal refractive powers), the direction of the steepest meridian, and the amount of corneal astigmatism. The non-contact tonometry function measures the intraocular pressure without contacting the eye.
NIDEK CO.,LTD.
TONOREF II
In Commercial Distribution
- 04987669100066 ()
- Ophthalmic tonometer, line-powered
- Bench-top keratometer
- Automated ophthalmic refractometer
The Construct Ankle Fusion Plate System consists of two anterior tibia-talus and a lateral tibia-talus-calcaneus arthrodesis plates. The plates are contoured to the peri articular anatomy and have tapered threaded holes which accept compression or locking threaded screws with a major thread diameter of 4.5 or 6.5mm. All plates and screws are manufactured from stainless steel or titanium. The system is intended for arthrodesis of the ankle joint and distal tibia, fractures, osteotomies, fusions, and replantation of small bones in the foot and ankle. Instruments are provided.
Ascension Orthopedics, Inc.
AFPIMP
Not in Commercial Distribution
- M268AFPIMP1 ()
- 10381780064497 ()
AFPIMP
- Internal orthopaedic fixation system, plate/screw, non-bioabsorbable, non-sterile
The EASY MAX Glucose Test Strips are intended for the quantitative measurement of glucose in fresh capillary whole blood samples drawn from the fingertips or forearm. The EASY MAX Glucose Test Strips must be used with the EASY MAX Blood Glucose Meter. Testing is done outside the body (In Vitro diagnostic use). They are indicated for use at home (over the counter [OTC]) by persons with diabetes, or in clinical settings by healthcare professionals, as an aid to monitor the effectiveness of diabetes control.
EPS BIO TECHNOLOGY CORP.
EASY MAX
In Commercial Distribution
- 10885017000277 ()
- 00885017000270 ()
- Glucose IVD, kit, enzyme spectrophotometry, rapid
Reusable
INTENDED USE/ CONTRAINDICATIONS
PrernierPro'" Air Transfer Mats are indicated for patients
• Who are unable to transfer or turn by their own effort. both assisted and unassisted
• Whose size and weight present possible risks to caregivers involved in the transfer of the patient
PRECAUTIONS & WARNINGS
• Use two or more caregivers during patient transfers
• Do not use transfer mat until user manual is reviewed.
• Do not leave patient unattended on inflated transfer mat
• Do not attempt to move patient on uninflated transfer mat.
• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)
AIR SUPPLY
Air supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.
INSTRUCTIONS FOR USE
1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.
2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.
3. Avoid having obstructions in path of transfer including lines and hoses
4. Hold onto handles during inflation.
5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.
6. Raise side rails, disconnect t air hose and undo safety straps.
7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient.
SVS LLC
3722
In Commercial Distribution
- 00818566019240 ()
- Length: 39 Inch
3722
- Patient transfer system, powered
Reusable
INTENDED USE/ CONTRAINDICATIONS
PrernierPro'" Air Transfer Mats are indicated for patients
• Who are unable to transfer or turn by their own effort. both assisted and unassisted
• Whose size and weight present possible risks to caregivers involved in the transfer of the patient
PRECAUTIONS & WARNINGS
• Use two or more caregivers during patient transfers
• Do not use transfer mat until user manual is reviewed.
• Do not leave patient unattended on inflated transfer mat
• Do not attempt to move patient on uninflated transfer mat.
• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)
AIR SUPPLY
Air supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.
INSTRUCTIONS FOR USE
1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.
2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.
3. Avoid having obstructions in path of transfer including lines and hoses
4. Hold onto handles during inflation.
5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.
6. Raise side rails, disconnect t air hose and undo safety straps.
7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient.
SVS LLC
3721
In Commercial Distribution
- 00818566019233 ()
- Length: 34 Inch
3721
- Patient transfer system, powered
Reusable
INTENDED USE/ CONTRAINDICATIONS
PrernierPro'" Air Transfer Mats are indicated for patients
• Who are unable to transfer or turn by their own effort. both assisted and unassisted
• Whose size and weight present possible risks to caregivers involved in the transfer of the patient
PRECAUTIONS & WARNINGS
• Use two or more caregivers during patient transfers
• Do not use transfer mat until user manual is reviewed.
• Do not leave patient unattended on inflated transfer mat
• Do not attempt to move patient on uninflated transfer mat.
• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)
AIR SUPPLY
Air supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.
INSTRUCTIONS FOR USE
1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.
2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.
3. Avoid having obstructions in path of transfer including lines and hoses
4. Hold onto handles during inflation.
5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.
6. Raise side rails, disconnect t air hose and undo safety straps.
7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient.
SVS LLC
3720
In Commercial Distribution
- 00818566019226 ()
- Length: 28 Inch
3720
- Patient transfer system, powered
INTENDED USE/ CONTRAINDICATIONS
PrernierPro'" Air Transfer Mats are indicated for patients
• Who are unable to transfer or turn by their own effort. both assisted and unassisted
• Whose size and weight present possible risks to caregivers involved in the transfer of the patient
PRECAUTIONS & WARNINGS
• Use two or more caregivers during patient transfers
• Do not use transfer mat until user manual is reviewed.
• Do not leave patient unattended on inflated transfer mat
• Do not attempt to move patient on uninflated transfer mat.
• The maximum safe working load for all PremierPro"' Air Transfer Mats is 1,000Ibs (450kg)
AIR SUPPLY
Air supply units may be compatible with PremierPro' " Air Transfer Mats if they provide 3 psi pressure and 80 cfm capacity. The hose used may be a standard 1.75" diameter hose that may be secured with a snap fastener or hook & loop fastener. Always refer the air supply unit’s operating Instructions, observing all precautions and warnings. All safety guidelines within the air supply unit' s operating Instructions should be followed.
INSTRUCTIONS FOR USE
1. Transfer surfaces should be close together and equal height or a slightly lower destination surface.
2. Air inlet pockets are located at the foot end of pad. Locate and insert air supply hose.
3. Avoid having obstructions in path of transfer including lines and hoses
4. Hold onto handles during inflation.
5. Move patient in a diagonal direction. head or feet end first until patient reaches destination and is centered.
6. Raise side rails, disconnect t air hose and undo safety straps.
7. Use appropriate turning and rolling technique to remove transfer mat from underneath patient.
SVS LLC
3701
In Commercial Distribution
- 10818566019179 ()
- 00818566019172 ()
- Length: 34 Inch
3701
- Patient transfer system, powered
The Spirotome Biopsy Needle Set is a family of core soft tissue biopsy medical devices to be used in humans to take out adequate samples of soft tissue from subdermal structures as breast, abdominal wall, thoracic wall, lymph nodes, thyroid, parotis, muscles, and liver.
The Spirotome Biopsy Needle Set contains:
• An introducer needle that consists of a cutting cannula
• A helical-tip receiving needle that has been sized to fit through the lumen of the cutting cannula
• A release element
This presentation has an external diameter of 14G (2.5 mm) and length of 350 mm.
Bioncise
SS14EN
In Commercial Distribution
- 05407005000212 ()
- 05407005001219 ()
SS14EN
- Soft-tissue biopsy needle, single-use
The Spirotome Biopsy Needle Set is a family of core soft tissue biopsy medical devices to be used in humans to take out adequate samples of soft tissue from subdermal structures as breast, abdominal wall, thoracic wall, lymph nodes, thyroid, parotis, muscles, and liver.
The Spirotome Biopsy Needle Set contains:
• An introducer needle that consists of a cutting cannula
• A helical-tip receiving needle that has been sized to fit through the lumen of the cutting cannula
• A release element
This presentation has an external diameter of 10G (4mm) and length of 350 mm.
Bioncise
SS10EN
In Commercial Distribution
- 05407005000205 ()
- 05407005001202 ()
SS10EN
- Soft-tissue biopsy needle, single-use