CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15040MR
In Commercial Distribution

  • 04540778162396 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.5 Fr
  • Distal Shaft Diameter; 3.5 Fr
  • Catheter Working Length; 900 mm
  • Balloon Length; 40 mm
  • Balloon Diameter; 1.5 mm
BD-B15040MR

  • Peripheral angioplasty balloon catheter, basic
CROSPERIO RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSPERIO RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
BD-B15020MR
In Commercial Distribution

  • 04540778162372 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.5 Fr
  • Distal Shaft Diameter; 3.5 Fr
  • Catheter Working Length; 900 mm
  • Balloon Length; 20 mm
  • Balloon Diameter; 1.5 mm
BD-B15020MR

  • Peripheral angioplasty balloon catheter, basic
The CNMC Model 206 is a medical dosimeter or medical electrometer that is capable of performing measurements of diagnostic and therapeutic amounts of ionizing radiation when an appropriate ionization chamber or diode dosimeter is connected.
CNMC CO., INC.
206
In Commercial Distribution

206

  • Radiation electrometer
The MediByte Jr. is a portable sleep data recorder used to record physiological signals during sleep while the patient is either at home or in a clinical environment. This is a new warranty replacement unit.
Braebon Medical Corporation
MBJR-WN
In Commercial Distribution

  • B140MBJRWN0 ()
MBJR-WN

  • Polysomnograph
The measurer is used to measure the 250mm K-wire in place and decide the compression screw length to implant. It is placed so that the thin side is aligned with the base of the K-wire.
NEWDEAL
119511ND
Not in Commercial Distribution

  • M248119511ND1 ()
  • 10381780044796 ()


  • Surgical depth gauge, reusable
The measurer is used to measure the 200/250mm K-wire in place and decide the screw length to implant. It is placed so that the thin side is aligned with the base of the K-wire.
NEWDEAL
119150ND
In Commercial Distribution

  • M248119150ND1 ()
  • 10381780044765 ()


  • Surgical depth gauge, reusable
PriMatrix is an acellular dermal tissue matrix. The device is supplied sterile and is provided in sheet form in a variety of sizes to be trimmed by the surgeon to meet the individual patient's needs.
TEI BIOSCIENCES INC.
6495-9-118
Not in Commercial Distribution

  • 10381780113706 ()

  • 8 x 8 x (0.20 - 1.04) cm x cm x mm
6495-9-118

  • Animal-derived wound matrix dressing
PriMatrix is an acellular dermal tissue matrix. The device is supplied sterile and is provided in sheet form in a variety of sizes to be trimmed by the surgeon to meet the individual patient's needs.
TEI BIOSCIENCES INC.
6495-9-116
Not in Commercial Distribution

  • 10381780113690 ()

  • 6 x 6 x (0.20 - 1.04) cm x cm x mm
6495-9-116

  • Animal-derived wound matrix dressing
PriMatrix is an acellular dermal tissue matrix. The device is supplied sterile and is provided in sheet form in a variety of sizes to be trimmed by the surgeon to meet the individual patient's needs.
TEI BIOSCIENCES INC.
6495-9-114
Not in Commercial Distribution

  • 10381780113683 ()

  • 4 x 4 x (0.20 - 1.04) cm x cm x mm
6495-9-114

  • Animal-derived wound matrix dressing
PriMatrix is an acellular dermal tissue matrix. The device is supplied sterile and is provided in sheet form in a variety of sizes to be trimmed by the surgeon to meet the individual patient's needs.
TEI BIOSCIENCES INC.
6495-9-108
Not in Commercial Distribution

  • 10381780113676 ()

  • 8 x 8 x (0.20 - 1.04) cm x cm x mm
6495-9-108

  • Animal-derived wound matrix dressing