RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3510UA2
In Commercial Distribution

  • 04540778167612 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 3.5 mm
DC-RY3510UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3010UA2
In Commercial Distribution

  • 04540778167599 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 3.0 mm
DC-RY3010UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2510UA2
In Commercial Distribution

  • 04540778167575 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 2.5 mm
DC-RY2510UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY2010UA2
In Commercial Distribution

  • 04540778167551 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 2.0 mm
DC-RY2010UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY1510UA1
In Commercial Distribution

  • 04540778167537 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 10 mm
  • Balloon Diameter; 1.5 mm
DC-RY1510UA1

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY5008UA2
In Commercial Distribution

  • 04540778167513 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 5.0 mm
DC-RY5008UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4508UA2
In Commercial Distribution

  • 04540778167490 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 6 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 4.5 mm
DC-RY4508UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY4008UA2
In Commercial Distribution

  • 04540778167476 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 4.0 mm
DC-RY4008UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3708UA2
In Commercial Distribution

  • 04540778167452 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.1 Fr
  • Distal Shaft Diameter; 2.7 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 3.75 mm
DC-RY3708UA2

  • Coronary angioplasty balloon catheter, basic
RX TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm).
KANEKA CORPORATION
DC-RY3508UA2
In Commercial Distribution

  • 04540778167438 ()

  • Maximum Guidewire Diameter; 0.014 inch
  • Compatible Guiding Catheter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 6 atm
  • Proximal Shaft Diameter; 2.0 Fr
  • Distal Shaft Diameter; 2.5 Fr
  • Catheter Working Length; 1450 mm
  • Balloon Length; 8 mm
  • Balloon Diameter; 3.5 mm
DC-RY3508UA2

  • Coronary angioplasty balloon catheter, basic
< 1 ... 974 975 976 977 978 ... 1000 >