MD-Temp is a temporary resin for formation of temporary fillings, and other temporary prosthesis, such as a crown or bridge, for use until a permanent restoration is fabricated. It is a hydraulic temporary restorative.
Meta Biomed Co., Ltd.
9213
In Commercial Distribution

  • 08806387892137 ()


  • Temporary dental crown/bridge
MD-Temp is a temporary resin for formation of temporary fillings, and other temporary prosthesis, such as a crown or bridge, for use until a permanent restoration is fabricated. It is a hydraulic temporary restorative.
Meta Biomed Co., Ltd.
9212
In Commercial Distribution

  • 08806387892120 ()


  • Temporary dental crown/bridge
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F60200ER
In Commercial Distribution

  • 04540778160439 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 6.0 mm
BD-F60200ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F50200ER
In Commercial Distribution

  • 04540778160415 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 5.0 mm
BD-F50200ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F40200ER
In Commercial Distribution

  • 04540778160392 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 4.0 mm
BD-F40200ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F30200ER
In Commercial Distribution

  • 04540778160378 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 3.0 mm
BD-F30200ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F25200ER
In Commercial Distribution

  • 04540778160354 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 2.5 mm
BD-F25200ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F20200ER
In Commercial Distribution

  • 04540778160330 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 4 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 3.4 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 200 mm
  • Balloon Diameter; 2.0 mm
BD-F20200ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F60150ER
In Commercial Distribution

  • 04540778160316 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 6.0 mm
BD-F60150ER

  • Peripheral angioplasty balloon catheter, basic
CROSSTELLA RX is a Percutaneous Transluminal Angioplasty (PTA) Balloon Dilatation Catheter for peripheral indications. CROSSTELLA RX is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.018 inches (0.46mm).
KANEKA CORPORATION
BD-F50150ER
In Commercial Distribution

  • 04540778160293 ()

  • Maximum Guidewire Diameter; 0.018 inch
  • Compatible Sheath Diameter; 5 Fr
  • Rated Burst Pressure; 14 atm
  • Nominal Pressure; 8 atm
  • Proximal Shaft Diameter; 4.1 Fr
  • Distal Shaft Diameter; 4.0 Fr
  • Catheter Working Length; 2000 mm
  • Balloon Length; 150 mm
  • Balloon Diameter; 5.0 mm
BD-F50150ER

  • Peripheral angioplasty balloon catheter, basic