GET /v1/devices/implantable/list (v1)
Returns a paginated list of devices that are implantable or accessories to an implant system along with some metadata about the device. If provided a UMLS single-use ticket, it also returns the SNOMED data.
This API is going to be deprecated. Please move to the v2 Implant List API.
Resource Information
format | URL |
---|---|
JSON |
https://accessgudid.awsprod.nlm.nih.gov/api/v1/devices/implantable/list.json |
XML |
https://accessgudid.awsprod.nlm.nih.gov/api/v1/devices/implantable/list.xml |
Parameters
parameter | type | default | description |
---|---|---|---|
ticket |
String |
null |
The single-use ticket used to access UMLS. A valid ticket will allow the SNOMED data to be returned in addition to all the other information normally returned without a ticket.
Example Value: ST-210847-HwTfbMTY100CWNe2owFF-cas
For information on how to generate a single-use ticket, please see the page on Generating UMLS Tickets. |
page |
Integer |
1 |
The page of paginated results to be returned
The response from the API will include X-Next-Page , X-Prev-Page , X-Total-Pages variables in the HTTP headers to allow paging back and forth.
|
per_page |
Integer[1,100] |
100 |
The number of results per page of paginated results |
from_date |
Date[(YY)YYMMDD or (YY)YY-MM-DD] |
null |
Results will only include those with a creation date after from_date (inclusive) |
to_date |
Date[(YY)YYMMDD or (YY)YY-MM-DD] |
null |
Results will only include those with a creation date before to_date (inclusive) |
Response Headers
header | type | description |
---|---|---|
X-Authenticated-Ticket |
Boolean |
The status of the single-use ticket |
X-Next-Page |
Integer |
The next page number |
X-Page |
Integer |
The current page of results |
X-Per-Page |
Integer |
How many devices are returned per page |
X-Prev-Page |
Integer |
The previous page number |
X-Total |
Integer |
The total number of devices |
X-Total-Pages |
Integer |
The total number of pages |
Examples
Without Ticket
JSON: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v1/devices/implantable/list.json?page=30&per_page=2
[{
deviceId: "00885556274866",
deviceIdIssuingAgency: "GS1",
brandName: "R3 ACETABULAR",
companyName: "Smith & Nephew, Inc.",
versionModelNumber: "71334850",
MRISafetyStatus: "Labeling does not contain MRI Safety Information",
labeledContainsNRL: "false",
gmdnPTName: [
"Ceramic acetabular liner"
]
}, {
deviceId: "00885556274910",
deviceIdIssuingAgency: "GS1",
brandName: "R3 ACETABULAR",
companyName: "Smith & Nephew, Inc.",
versionModelNumber: "71334852",
MRISafetyStatus: "Labeling does not contain MRI Safety Information",
labeledContainsNRL: "false",
gmdnPTName: [
"Ceramic acetabular liner"
]
}]
XML: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v1/devices/implantable/list.xml?page=30&per_page=2
<result type="array">
<result>
<deviceId>00885556274866</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<brandName>R3 ACETABULAR</brandName>
<companyName>Smith & Nephew, Inc.</companyName>
<versionModelNumber>71334850</versionModelNumber>
<MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus>
<labeledContainsNRL>false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Ceramic acetabular liner</gmdnPTName>
</gmdnPTName>
</result>
<result>
<deviceId>00885556274910</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<brandName>R3 ACETABULAR</brandName>
<companyName>Smith & Nephew, Inc.</companyName>
<versionModelNumber>71334852</versionModelNumber>
<MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus>
<labeledContainsNRL>false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Ceramic acetabular liner</gmdnPTName>
</gmdnPTName>
</result>
</result>
With Ticket
JSON: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v1/devices/implantable/list.json?ticket=ST-210847-HwTfbMTY100CWNe2owFF-cas&page=30&per_page=2
[{
deviceId: "08022057012753",
deviceIdIssuingAgency: "GS1",
brandName: "CARBOMEDICS STANDARD",
companyName: "SORIN GROUP ITALIA SRL",
versionModelNumber: "M7",
MRISafetyStatus: "MR Conditional",
labeledContainsNRL: "false",
gmdnPTName: [
"Mitral bi-leaflet heart valve prosthesis"
],
snomed: [{
snomedIdentifier: "701898003",
snomedCTName: "Mitral bi-leaflet heart valve prosthesis"
}]
}, {
deviceId: "08022057012760",
deviceIdIssuingAgency: "GS1",
brandName: "CARBOMEDICS REDUCED",
companyName: "SORIN GROUP ITALIA SRL",
versionModelNumber: "R5",
MRISafetyStatus: "MR Conditional",
labeledContainsNRL: "false",
gmdnPTName: [
"Aortic bi-leaflet heart valve prosthesis"
],
snomed: [{
snomedIdentifier: "701897008",
snomedCTName: "Aortic bi-leaflet heart valve prosthesis"
}]
}]
XML: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v1/devices/implantable/list.xml?ticket=ST-210847-HwTfbMTY100CWNe2owFF-cas&page=30&per_page=2
<result type="array">
<result>
<deviceId>08022057012753</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<brandName>CARBOMEDICS STANDARD</brandName>
<companyName>SORIN GROUP ITALIA SRL</companyName>
<versionModelNumber>M7</versionModelNumber>
<MRISafetyStatus>MR Conditional</MRISafetyStatus>
<labeledContainsNRL>false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Mitral bi-leaflet heart valve prosthesis</gmdnPTName>
</gmdnPTName>
<snomed type="array">
<snomed>
<snomedIdentifier>701898003</snomedIdentifier>
<snomedCTName>Mitral bi-leaflet heart valve prosthesis</snomedCTName>
</snomed>
</snomed>
</result>
<result>
<deviceId>08022057012760</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<brandName>CARBOMEDICS REDUCED</brandName>
<companyName>SORIN GROUP ITALIA SRL</companyName>
<versionModelNumber>R5</versionModelNumber>
<MRISafetyStatus>MR Conditional</MRISafetyStatus>
<labeledContainsNRL>false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Aortic bi-leaflet heart valve prosthesis</gmdnPTName>
</gmdnPTName>
<snomed type="array">
<snomed>
<snomedIdentifier>701897008</snomedIdentifier>
<snomedCTName>Aortic bi-leaflet heart valve prosthesis</snomedCTName>
</snomed>
</snomed>
</result>
</result>