GET /devices/implantable/list
Returns a paginated list of devices that are implantable or accessories to an implant system along with some metadata about the device. If provided a UMLS single-use ticket, it also returns the SNOMED data.
Resource Information
format | URL |
---|---|
JSON |
https://accessgudid.awsprod.nlm.nih.gov/api/v2/devices/implantable/list.json |
XML |
https://accessgudid.awsprod.nlm.nih.gov/api/v2/devices/implantable/list.xml |
Parameters
parameter | type | default | description |
---|---|---|---|
ticket |
String |
null |
The single-use ticket used to access UMLS. A valid ticket will allow the SNOMED data to be returned in addition to all the other information normally returned without a ticket.
Example Value: ST-210847-HwTfbMTY100CWNe2owFF-cas
For information on how to generate a single-use ticket, please see the page on Generating UMLS Tickets. |
page |
Integer |
1 |
The page of paginated results to be returned
The response from the API will include X-Next-Page , X-Prev-Page , X-Total-Pages variables in the HTTP headers to allow paging back and forth.
|
per_page |
Integer[1,100] |
100 |
The number of results per page of paginated results |
from_date |
Date[(YY)YYMMDD or (YY)YY-MM-DD] |
null |
Results will only include those with a version date after from_date (inclusive) |
to_date |
Date[(YY)YYMMDD or (YY)YY-MM-DD] |
null |
Results will only include those with a version date before to_date (inclusive) |
Response Headers
header | type | description |
---|---|---|
X-Authenticated-Ticket |
Boolean |
The status of the single-use ticket |
X-Next-Page |
Integer |
The next page number |
X-Page |
Integer |
The current page of results |
X-Per-Page |
Integer |
How many devices are returned per page |
X-Prev-Page |
Integer |
The previous page number |
X-Total |
Integer |
The total number of devices |
X-Total-Pages |
Integer |
The total number of pages |
Examples
Without Ticket
JSON: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v2/devices/implantable/list.json?page=30&per_page=2
{
metadata: {
page: 30,
totalPages: 329678,
totalResults: 659356
},
devices: [
{
deviceId: "10885862001856",
deviceIdIssuingAgency: "GS1",
publicDeviceRecordKey: "103606eb-6715-4378-aef9-97d21394478a",
publicVersionNumber: 2,
publicVersionDate: "2018-02-10T00:00:00.000Z",
brandName: "Optetrak Logic",
companyName: "Exactech, Inc.",
versionModelNumber: "02-012-35-3511",
dunsNumber: "157565946",
MRISafetyStatus: "Labeling does not contain MRI Safety Information",
labeledContainsNRL: false,
gmdnPTName: [
"Tibial insert"
],
deviceRecordStatus: "Published",
creationDate: "2018-03-15T22:57:33.925Z"
},
{
deviceId: "10885862001863",
deviceIdIssuingAgency: "GS1",
publicDeviceRecordKey: "a9b06909-7100-4602-a9e8-618b1a96e470",
publicVersionNumber: 2,
publicVersionDate: "2018-02-10T00:00:00.000Z",
brandName: "Optetrak Logic",
companyName: "Exactech, Inc.",
versionModelNumber: "02-012-35-3513",
dunsNumber: "157565946",
MRISafetyStatus: "Labeling does not contain MRI Safety Information",
labeledContainsNRL: false,
gmdnPTName: [
"Tibial insert"
],
deviceRecordStatus: "Published",
creationDate: "2018-03-15T22:57:33.890Z"
}
]
}
XML: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v2/devices/implantable/list.xml?page=30&per_page=2
<result>
<metadata>
<page type="integer">30</page>
<totalPages type="integer">329678</totalPages>
<totalResults type="integer">659356</totalResults>
</metadata>
<devices type="array">
<device>
<deviceId>10885862001856</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<publicDeviceRecordKey>103606eb-6715-4378-aef9-97d21394478a</publicDeviceRecordKey>
<publicVersionNumber type="integer">2</publicVersionNumber>
<publicVersionDate type="dateTime">2018-02-10T00:00:00Z</publicVersionDate>
<brandName>Optetrak Logic</brandName>
<companyName>Exactech, Inc.</companyName>
<versionModelNumber>02-012-35-3511</versionModelNumber>
<dunsNumber>157565946</dunsNumber>
<MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus>
<labeledContainsNRL type="boolean">false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Tibial insert</gmdnPTName>
</gmdnPTName>
<deviceRecordStatus>Published</deviceRecordStatus>
<creationDate type="dateTime">2018-03-15T22:57:33Z</creationDate>
</device>
<device>
<deviceId>10885862001863</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<publicDeviceRecordKey>a9b06909-7100-4602-a9e8-618b1a96e470</publicDeviceRecordKey>
<publicVersionNumber type="integer">2</publicVersionNumber>
<publicVersionDate type="dateTime">2018-02-10T00:00:00Z</publicVersionDate>
<brandName>Optetrak Logic</brandName>
<companyName>Exactech, Inc.</companyName>
<versionModelNumber>02-012-35-3513</versionModelNumber>
<dunsNumber>157565946</dunsNumber>
<MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus>
<labeledContainsNRL type="boolean">false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Tibial insert</gmdnPTName>
</gmdnPTName>
<deviceRecordStatus>Published</deviceRecordStatus>
<creationDate type="dateTime">2018-03-15T22:57:33Z</creationDate>
</device>
</devices>
</result>
With Ticket
JSON: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v2/devices/implantable/list.json?ticket=ST-210847-HwTfbMTY100CWNe2owFF-cas&page=30&per_page=2
{
metadata: {
authenticatedTicket: true,
page: 30,
totalPages: 329678,
totalResults: 659356
},
devices: [
{
deviceId: "10885862001856",
deviceIdIssuingAgency: "GS1",
publicDeviceRecordKey: "103606eb-6715-4378-aef9-97d21394478a",
publicVersionNumber: 2,
publicVersionDate: "2018-02-10T00:00:00.000Z",
brandName: "Optetrak Logic",
companyName: "Exactech, Inc.",
versionModelNumber: "02-012-35-3511",
dunsNumber: "157565946",
MRISafetyStatus: "Labeling does not contain MRI Safety Information",
labeledContainsNRL: false,
gmdnPTName: [
"Tibial insert"
],
snomed: [
{
snomedIdentifier: "465042008",
snomedCTName: "Tibial insert (physical object)"
}
],
deviceRecordStatus: "Published",
creationDate: "2018-03-15T22:57:33.925Z"
},
{
deviceId: "10885862001863",
deviceIdIssuingAgency: "GS1",
publicDeviceRecordKey: "a9b06909-7100-4602-a9e8-618b1a96e470",
publicVersionNumber: 2,
publicVersionDate: "2018-02-10T00:00:00.000Z",
brandName: "Optetrak Logic",
companyName: "Exactech, Inc.",
versionModelNumber: "02-012-35-3513",
dunsNumber: "157565946",
MRISafetyStatus: "Labeling does not contain MRI Safety Information",
labeledContainsNRL: false,
gmdnPTName: [
"Tibial insert"
],
snomed: [
{
snomedIdentifier: "465042008",
snomedCTName: "Tibial insert (physical object)"
}
],
deviceRecordStatus: "Published",
creationDate: "2018-03-15T22:57:33.890Z"
}
]
}
XML: GET
https://accessgudid.awsprod.nlm.nih.gov/api/v2/devices/implantable/list.xml?ticket=ST-210847-HwTfbMTY100CWNe2owFF-cas&page=30&per_page=2
<result>
<metadata>
<page type="integer">30</page>
<totalPages type="integer">329678</totalPages>
<totalResults type="integer">659356</totalResults>
</metadata>
<devices type="array">
<device>
<deviceId>10885862001856</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<publicDeviceRecordKey>103606eb-6715-4378-aef9-97d21394478a</publicDeviceRecordKey>
<publicVersionNumber type="integer">2</publicVersionNumber>
<publicVersionDate type="dateTime">2018-02-10T00:00:00Z</publicVersionDate>
<brandName>Optetrak Logic</brandName>
<companyName>Exactech, Inc.</companyName>
<versionModelNumber>02-012-35-3511</versionModelNumber>
<dunsNumber>157565946</dunsNumber>
<MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus>
<labeledContainsNRL type="boolean">false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Tibial insert</gmdnPTName>
</gmdnPTName>
<snomed type="array">
<snomed>
<snomedIdentifier>465042008</snomedIdentifier>
<snomedCTName>Tibial insert (physical object)</snomedCTName>
</snomed>
</snomed>
<deviceRecordStatus>Published</deviceRecordStatus>
<creationDate type="dateTime">2018-03-15T22:57:33Z</creationDate>
</device>
<device>
<deviceId>10885862001863</deviceId>
<deviceIdIssuingAgency>GS1</deviceIdIssuingAgency>
<publicDeviceRecordKey>a9b06909-7100-4602-a9e8-618b1a96e470</publicDeviceRecordKey>
<publicVersionNumber type="integer">2</publicVersionNumber>
<publicVersionDate type="dateTime">2018-02-10T00:00:00Z</publicVersionDate>
<brandName>Optetrak Logic</brandName>
<companyName>Exactech, Inc.</companyName>
<versionModelNumber>02-012-35-3513</versionModelNumber>
<dunsNumber>157565946</dunsNumber>
<MRISafetyStatus>Labeling does not contain MRI Safety Information</MRISafetyStatus>
<labeledContainsNRL type="boolean">false</labeledContainsNRL>
<gmdnPTName type="array">
<gmdnPTName>Tibial insert</gmdnPTName>
</gmdnPTName>
<snomed type="array">
<snomed>
<snomedIdentifier>465042008</snomedIdentifier>
<snomedCTName>Tibial insert (physical object)</snomedCTName>
</snomed>
</snomed>
<deviceRecordStatus>Published</deviceRecordStatus>
<creationDate type="dateTime">2018-03-15T22:57:33Z</creationDate>
</device>
</devices>
</result>